Features

ā— Maximum output power: 300W
ā— Six output modes: (1) pure cut, (2) mixed cut 1, (3) mixed cut 2, (4) electrocoagulation 1, (5) electrocoagulation 2, (6) Bipolar condensate;
ā— Electric cut mode: pure cut 100% cut, mixed cut 1 70 % cut, 30% coagulation; mixed cut 2 50 % cut, 50% coagulation;
ā— Pure cut: Maximum output power 300W, enabling easy surgery on any tissues and structures;
ā— Mixed cut: Applicable for any tissue, good coagulation effect when conducting cutting;
ā— Electrocoagulation 1: Applicable for general open surgery and fine surgical point coagulation, featuring deep tissue coagulation layer and excellent coagulation effect;
ā— Electrocoagulation 2: Applicable for general open surgery and fine surgical surface coagulation;
ā— Bipolar coagulation: When the tissues achieve the effect of coagulation, the output power will begin to reduce slowly to achieve good coagulation effect;
ā— Panel operation: Overall microcomputer automatic control, three-zone (LED) digital display, key function/power, switch/ settings, waterproof panel design;
ā— Automatic adjustment: Automatically fine adjust power in a certain range to ensure the consistency of the cutting effect;
ā— Automatic recognition: Neutral unipolar/bipolar plate automatic recognition, when using the dual-circuit plates and the contact area less than 60%, it should automatically stop the power output and send sound-light alarm until the contact area returns to normal, which could effectively avoid burning patients by plates.
ā—
Application range:Used in endoscopic, hysteroscopy, anorectal, general surgery, etc

Technical Specifications

  • Power Supply: 220V ±22V
  • Operating Frequency: 530KHz ±2Hz
  • Power Rating: 1400VA
  • Working Modes:
    • Monopolar Cut:
      • Pure Cut: 1W~100W (Load 300Ī©)
      • Blend 1: 1W~80W (Load 300Ī©)
      • Blend 2: 1W~60W (Load 300Ī©)
    • Monopolar Coag:
      • Monopolar Coag: 1W~50W (Load 300Ī©)
    • Bipolar Coag:
      • Bipolar Coag: 1W~50W (Load 100Ī©)


Detailed Images
$344.75

Original: $985.00

-65%
Portable Electrosurgical Unit High Frequency Electrosurgical Unit MSL100D—

$985.00

$344.75

Product Information

Shipping & Returns

Description

Portable Electrosurgical Unit High Frequency Electrosurgical Unit MSL100D

Ā 

Ā 

Features

ā— Maximum output power: 300W
ā— Six output modes: (1) pure cut, (2) mixed cut 1, (3) mixed cut 2, (4) electrocoagulation 1, (5) electrocoagulation 2, (6) Bipolar condensate;
ā— Electric cut mode: pure cut 100% cut, mixed cut 1 70 % cut, 30% coagulation; mixed cut 2 50 % cut, 50% coagulation;
ā— Pure cut: Maximum output power 300W, enabling easy surgery on any tissues and structures;
ā— Mixed cut: Applicable for any tissue, good coagulation effect when conducting cutting;
ā— Electrocoagulation 1: Applicable for general open surgery and fine surgical point coagulation, featuring deep tissue coagulation layer and excellent coagulation effect;
ā— Electrocoagulation 2: Applicable for general open surgery and fine surgical surface coagulation;
ā— Bipolar coagulation: When the tissues achieve the effect of coagulation, the output power will begin to reduce slowly to achieve good coagulation effect;
ā— Panel operation: Overall microcomputer automatic control, three-zone (LED) digital display, key function/power, switch/ settings, waterproof panel design;
ā— Automatic adjustment: Automatically fine adjust power in a certain range to ensure the consistency of the cutting effect;
ā— Automatic recognition: Neutral unipolar/bipolar plate automatic recognition, when using the dual-circuit plates and the contact area less than 60%, it should automatically stop the power output and send sound-light alarm until the contact area returns to normal, which could effectively avoid burning patients by plates.
ā—
Application range:Used in endoscopic, hysteroscopy, anorectal, general surgery, etc

Technical Specifications

  • Power Supply: 220V ±22V
  • Operating Frequency: 530KHz ±2Hz
  • Power Rating: 1400VA
  • Working Modes:
    • Monopolar Cut:
      • Pure Cut: 1W~100W (Load 300Ī©)
      • Blend 1: 1W~80W (Load 300Ī©)
      • Blend 2: 1W~60W (Load 300Ī©)
    • Monopolar Coag:
      • Monopolar Coag: 1W~50W (Load 300Ī©)
    • Bipolar Coag:
      • Bipolar Coag: 1W~50W (Load 100Ī©)


Detailed Images
Portable Electrosurgical Unit High Frequency Electrosurgical Unit MSL100D | ALISA